Example drawing, not a real project

Roofing take-off from a hipped roof plan

Plan and slope areas, ridge, hips, eaves, gutters, downpipes and rooflights from a roof plan. Drawing: Bungalow roof plan, 1:100. Read with the Roofing trade profile on 15 November 2026.

Example drawing: Bungalow roof plan, 1:100
Example drawing drawn by QuantRead (CC BY 4.0). Download the PDF and try it yourself.

Take-off produced

ItemDetailQtyUnitConfidenceNote
Roof area on plan35 deg pitched; flat 0. Rooflights not deducted96m2highPage 1
Roof area on slope35 deg pitch, gross to eaves117.2m2highPage 1
RidgeSingle ridge, written 40004mhighPage 1
Hips4 nr equal hips, true (sloping) length25.2mmediumPage 1
ValleysFully hipped; no valley lines0mhighPage 1
EavesHipped; entire perimeter is eaves40mhighPage 1
VergesNo gables0mhighPage 1
GuttersHalf-round; diameter not stated40mhighPage 1
Downpipes / RWPs68 mm; vertical length not on this plan4nrhighPage 1
Rooflights780 x 980 each2nrhighPage 1
Rooflight opening area (not deducted)2 x 0.780 x 0.980; plane of size not stated1.5m2mediumPage 1

Exports from this run: CSV · PDF report

These figures are the engine’s output, unedited. In QuantRead you review every line, correct anything that is wrong and add your own items before you export or quote.

Our check against the drawing

We drew this example, so we know the figures its written dimensions give.

ItemQuantReadFrom the drawingComment
Roof area on plan96 m²96 m²12 x 8 m. Matches.
Roof area on slope (35°)117.2 m²117.19 m²96 ÷ cos 35°. Matches.
Ridge4 m4 mMatches.
Hips (4 nr, true length)25.2 m25.25 mEach hip 6.31 m at 35°. Matches (rounded).
Eaves and gutters40 m40 mPerimeter 2 x (12 + 8). Matches.
Downpipes / rooflights4 nr / 2 nr4 nr / 2 nrMatches.

No manual correction was needed on this sample.

How QuantRead measured it

Scale and sheet

Page 1 · Bungalow - roof plan · plan · A3
Scale: 1:100 @ A3
Checked against: Not scaled. Drawing states do not scale; written sizes 12000, 8000 and 4000 used.

How each line was measured

PgItemQtyUnitBasisConf.Method
1Roof area on plan
Whole roof to eaves line
96m2dimensionedhigh12.0 m x 8.0 m from written eaves-line sizes
1Roof area on slope
All slopes
117.2m2dimensionedhighPlan area 96.0 / cos(35 deg) = 117.2 m2
1Ridge
Central ridge, parallel to long eaves
4mdimensionedhighWritten ridge length 4000 mm
1Hips
Four corners to ridge ends
25.2mdimensionedmediumRidge taken as centred: plan run 4.0 x 4.0 m each. Rise 4.0 x tan(35 deg). True length 6.3 m x 4
1Valleys
None on plan
0mcountedhighNo valleys drawn or noted
1Eaves
All four sides to eaves line
40mdimensionedhigh2 x (12.0 + 8.0) m
1Verges
None
0mcountedhighHipped to all corners; gutter noted to all eaves
1Gutters
All eaves
40mdimensionedhighNote: gutter to all eaves, equal to eaves 40.0 m
1Downpipes / RWPs
One at each corner
4nrcountedhigh4 RWP tags plus note of 4 nr 68 mm downpipes
1Rooflights
On slope below ridge, as drawn
2nrcountedhigh2 RL symbols; schedule states 2 nr
1Rooflight opening area (not deducted)
2 nr rooflights
1.5m2dimensionedmediumProduct of written rooflight sizes; confirm if plan or unit size before deducting from tiling

Check on site

  • p1: Downpipe drop lengths, shoes and offsets are not on this plan.
  • p1: Half-round gutter diameter is not stated.
  • p1: Confirm ridge is central and all four hips are equal; hip lengths are not dimensioned.
  • p1: Confirm whether rooflight openings are to be deducted from tiling, and the plane of the 780 x 980 size.
  • p1: Tile manufacturer, gauge/lap and ridge/hip fixing system are not stated. Fascia and soffit are not shown.

Assumptions

  • Ridge is centred, so each hip has equal plan runs of 4.0 m along the length and 4.0 m across the width.
  • Hip quantity is true sloping length, not plan length.
  • Roof areas are gross to the eaves line; rooflight openings are not deducted.
  • Gutter length equals the eaves-line perimeter; no deduction at outlets or corners.
  • 780 x 980 is the stated rooflight size; whether that is plan or on-slope is not stated.

Scope notes

  • Fully hipped roof, all slopes 35 degree pitch, interlocking concrete tiles.
  • Plan to eaves line 12000 x 8000. Ridge 4000. Gutter to all eaves.
  • 4 nr 68 mm downpipes at corners. 2 nr rooflights 780 x 980. No valleys or verges shown.

AI estimate of quantities only. Not a price, a survey or a bill of quantities. Check every quantity against the drawings and on site before you quote or order.

Try your own drawing free

Upload one PDF drawing (up to 3 pages), pick your trade and get an editable take-off like this one.

Try it free – 1 drawing, up to 3 pagesSee pricing

More samples

Roofing take-off from a hipped roof plan (Sample) | QuantRead