Example drawing, not a real project

Electrical first-fix take-off from a lighting and power layout

Sockets, light points, switches, detectors and the consumer unit counted from a layout. Drawing: Ground floor small power and lighting layout, 1:50. Read with the Electrical trade profile on 15 November 2026.

Example drawing: Ground floor small power and lighting layout, 1:50
Example drawing drawn by QuantRead (CC BY 4.0). Download the PDF and try it yourself.

Take-off produced

ItemDetailQtyUnitConfidenceNote
Twin 13 A switched socket outletstwin 13 A switched10nrhighPage 1
Ceiling light pointsceiling light point; luminaire type not stated6nrhighPage 1
One-way light switchesone-way4nrhighPage 1
Data / TV pointsnone shown0nrhighPage 1
Mains smoke detectorSD mains smoke detector1nrhighPage 1
Heat detectorHD heat detector1nrhighPage 1
Consumer unitconsumer unit; ways and rating not stated1nrhighPage 1

Exports from this run: CSV · PDF report

These figures are the engine’s output, unedited. In QuantRead you review every line, correct anything that is wrong and add your own items before you export or quote.

Our check against the drawing

We drew this example, so we know the figures its written dimensions give.

ItemQuantReadFrom the drawingComment
Twin sockets10 nr10 nrLounge 4, kitchen 5, hall 1. Matches.
Light points6 nr6 nrMatches.
Switches4 nr4 nrMatches.
Smoke and heat detectors1 + 1 nr1 + 1 nrMatches.
Consumer unit1 nr1 nrMatches.
Cable runsnot measurednot drawnCorrectly left blank: no cable routes are drawn.

No manual correction was needed on this sample.

How QuantRead measured it

Scale and sheet

Page 1 · Ground floor - small power and lighting layout · plan · A3
Scale: 1:50 @ A3
Checked against: Not used. Written overall 11000 mm and 6600 mm are on the plan; title block says do not scale.

How each line was measured

PgItemQtyUnitBasisConf.Method
1Twin 13 A switched socket outlets
Lounge 4, kitchen 5, hall 1
10nrcountedhighCounted boxed (2) symbols once on the plan; overlap tiles not double-counted.
1Ceiling light points
Lounge 2, kitchen 2, hall 2
6nrcountedhighCounted circled-X symbols per legend.
1One-way light switches
Lounge 1, kitchen 1, hall 2
4nrcountedhighCounted S symbols. The S beside the DB box is a separate switch.
1Data / TV points
None on this sheet
0nrcountedhighNo data or TV symbols on the plan or in the legend.
1Mains smoke detector
Hall
1nrcountedhighCounted SD symbol.
1Heat detector
Kitchen
1nrcountedhighCounted HD symbol.
1Consumer unit
Hall, north-east
1nrcountedhighCounted one DB symbol.
1Indicative cable / containment runs
Not shown
not measuredmcountedlowNo cable or containment lines on the plan; length not guessed.

Check on site

  • p1: Cable and containment routes, sizes and lengths are not shown.
  • p1: Luminaire types are not stated.
  • p1: Accessory mounting heights are not shown.
  • p1: Consumer unit rating and number of ways are not shown.
  • p1: Confirm whether data or TV points are on another drawing; none shown here.
  • p1: No cooker or other dedicated appliance outlet is shown; confirm if required.
  • p1: Circuiting is not shown; all switches are tagged one-way.

Assumptions

  • Each legend symbol is one outlet, point or switch.
  • All boxed 2 symbols are twin 13 A switched sockets; no single sockets shown.
  • Circled X symbols are ceiling light points only; luminaire type is not assumed.
  • The two S symbols either side of the lounge/kitchen wall are two separate one-way switches.
  • The S beside the DB box is a switch, not part of the consumer unit label.

Scope notes

  • Ground floor small power and lighting symbol layout only.
  • Take-off is a count of legend symbols. No cable routes, containment or circuit chart.
  • Demonstration drawing, not a real project.

AI estimate of quantities only. Not a price, a survey or a bill of quantities. Check every quantity against the drawings and on site before you quote or order.

Try your own drawing free

Upload one PDF drawing (up to 3 pages), pick your trade and get an editable take-off like this one.

Try it free – 1 drawing, up to 3 pagesSee pricing

More samples

Electrical first-fix take-off from a lighting and power layout | QuantRead