Take-off software for your trade

Each trade has its own measurement profile: QuantRead measures the items that trade prices from, in the units it prices in. Pick yours to see what it measures and a worked example.

Sealant and mastic take-off

  • Window perimeter joints (m), one bead unless the drawing says otherwise
  • Door perimeter joints (m)
  • Movement and expansion joints (m)

Windows and doors take-off

  • Window and door openings by type and tag (W01, D-02 and so on)
  • Sizes from the schedule, written dimensions, or scaled from the elevation
  • Perimeter metres per type, and sides-and-head only for doors

Drylining and plastering take-off

  • Partition lengths (m), split by partition type where a key is shown
  • Wall area less openings, by room (m²)
  • Ceiling area by room (m²)

Flooring take-off

  • Floor area per room and finish (m²)
  • Perimeters for gripper, edging and skirting (m)
  • Thresholds and door bars (nr)

Roofing take-off

  • Roof area on plan (m²), flat and pitched kept apart
  • Roof area on slope, pitch-corrected (m²)
  • Ridges, hips and valleys (m)

Brickwork take-off

  • Wall area by type, less openings (m²)
  • Lintels (nr)
  • DPC length (m)

Electrical take-off

  • Socket outlets, single and double (nr)
  • Light fittings and points by fitting type (nr)
  • Switches (nr)

Plumbing and heating take-off

  • Sanitaryware: WCs, basins, baths, showers, sinks (nr)
  • Radiators, by size where shown (nr)
  • Boilers, cylinders and plant (nr)

HVAC and ventilation take-off

  • Extract fans and grilles (nr)
  • Ductwork runs (m)
  • Plus plumbing items: sanitaryware, radiators, plant, pipe runs

Fire-stopping take-off

  • Service penetrations through fire-rated walls and floors, by service type and size band (nr)
  • Fire-rated linear joints: head-of-wall and slab edge (m)
  • Fire door frame perimeters (m)

Tiling take-off

  • Wall tiling areas (m²)
  • Floor area by room and finish (m²)
  • Perimeters and edge trims (m)

Joinery and carpentry take-off

  • Internal doors and frames by size and fire rating (nr)
  • External doors (nr)
  • Skirting (m)

Cladding take-off

  • Cladding area by type, less openings (m²)
  • Trims, flashings and corners (m)
  • Panel joints (m)

Groundworks and drainage take-off

  • Excavation and reduced-level areas (m²)
  • Excavation volume, only where depths are shown (m³)
  • Strip foundation lengths (m)

Painting and decorating take-off

  • Wall area less openings, by room (m²)
  • Ceiling area by room (m²)
  • Doors and frames, each side counted (nr)

Not sure which profile to use?

For a general measure of rooms, areas, perimeters and openings, use the general profile described on our quantity surveying software page. You can read the same drawing with more than one profile.

Measure your next drawing in minutes

Upload a PDF, pick your trade, and get an editable take-off with the scale used and a check-on-site list.

Try it free – 1 drawing, up to 3 pagesSee pricing
Take-Off Software by Trade | QuantRead