Example take-off: one facade elevation, sealant applicator profile
This is a real result from our October 2026 tests, with the project, client, drawing numbers and third-party names removed. Nothing has been edited apart from that. It shows both what the reader does well and where it needs checking. Read the case study for how it compared with a manual take-off.
Take-off schedule
| Item | Detail | Qty | Unit | Confidence | Note |
|---|---|---|---|---|---|
| Window perimeter sealant (full perimeter) | external, both faces not included | 175.4 | m | medium | Page 1 |
| Window openings | 31 | nr | medium | Page 1 | |
| Door perimeter sealant (full perimeter) (ASSUMED sizes: check) | external, both faces not included | 45.6 | m | low | Page 1 |
| Door openings | 7 | nr | medium | Page 1 | |
| Curtain-wall / glazed-screen bay joints (156 bays, NOT in opening counts) (ASSUMED sizes: check) | upper bound: bays share mullions/transoms, so shared joints are counted twice here | 1391.5 | m | low | Page 1 |
| Service penetrations through walls (ESTIMATE: fire rating not shown) | power cable | 2 | nr | low | Page 1 |
| Vertical EWI movement joint — tower core/curtain-wall junction | joint width not stated; substrate EWI (proprietary) to curtain wall; L2 (39110) to L14 (74705) | 35.6 | m | medium | Page 1 |
| Vertical EWI movement joint — low block far-left return | joint width not stated; substrate EWI render; written 5666.27 mm; dashed-red added MJ (rev P3) | 5.7 | m | high | Page 1 |
| Vertical EWI movement joints — low block (tower junction and far-right return) | joint width not stated; substrate EWI render; 2 nr x 5081.75 mm; dashed-red added MJs (rev P3) | 10.2 | m | high | Page 1 |
| Horizontal EWI movement joints — tower curtain wall (head, No.71, No.56, No.39) | joint width not stated; substrate EWI to curtain wall; 4 nr x 17840.34 mm (No.39 dimensioned, other three span the same vertical edges) | 71.4 | m | medium | Page 1 |
| Horizontal EWI movement joint — tower base (No.21) | joint width not stated; substrate EWI to curtain wall; written 13155.41 mm — shorter than the joints above, confirm endpoints | 13.2 | m | medium | Page 1 |
Scale and sheet
Page 1 · Overall north elevation (render and spandrel) · elevation · A1
Scale: 1:150
Checked against: Level datums: L13 (71720) to L14 (74705) = 2985 mm and L0 (30000) to L1 (33870) = 3870 mm, consistent with the drawn storey spacing at 1:150.
No scale found in the drawing text. Lengths and areas come only from written dimensions or the AI reading the scale bar.
Scale: 1:150
Checked against: Level datums: L13 (71720) to L14 (74705) = 2985 mm and L0 (30000) to L1 (33870) = 3870 mm, consistent with the drawn storey spacing at 1:150.
No scale found in the drawing text. Lengths and areas come only from written dimensions or the AI reading the scale bar.
How each line was measured
| Pg | Item | Qty | Unit | Basis | Conf. | Method |
|---|---|---|---|---|---|---|
| 1 | Window perimeter sealant (full perimeter) 0.15-0.23 1500x1400 x9, 1.11-1.18 2400x1500 x8, Lobby 900x1200 x12, No.15 1200x1400 x2 | 175.4 | m | scaled | medium | Worked out in code: sum of 2 x (width + height) for 31 windows (4 size types) using sizes from: scaled. Sides and head only: 129.5 m. |
| 1 | Window openings | 31 | nr | counted | medium | Openings listed with sizes, counted in code. |
| 1 | Door perimeter sealant (full perimeter) (ASSUMED sizes: check) D-entrance 1800x2100 x2, D-single 900x2100 x5 | 45.6 | m | assumed | low | Worked out in code: sum of 2 x (width + height) for 7 doors (2 size types) using sizes from: typical. Sides and head only: 37.5 m. |
| 1 | Door openings | 7 | nr | counted | medium | Openings listed with sizes, counted in code. |
| 1 | Curtain-wall / glazed-screen bay joints (156 bays, NOT in opening counts) (ASSUMED sizes: check) CW-bay 1490x2970 x156 | 1391.5 | m | assumed | low | Worked out in code: 2 x (width + height) per bay for 156 bays. Kept separate from windows; confirm against the curtain-wall bay study before pricing. |
| 1 | Service penetrations through walls (ESTIMATE: fire rating not shown) power cable <=50mm x2 (North elevation, right side of tower; one cable noted 900 mm from corner, entry ) | 2 | nr | counted | low | Counted where pipes, ducts, cables or trays cross a wall line on the drawing. The drawing does not show which walls/floors are fire-rated: check the fire strategy before pricing. |
| 1 | Vertical EWI movement joint — tower core/curtain-wall junction North elevation, left edge of tower curtain wall | 35.6 | m | dimensioned | medium | Horizontal MJs fall every 3 storeys (~8900 mm), matching level datums at L2, L5, L8, L11, L14; vertical joint runs between the lowest and highest. |
| 1 | Vertical EWI movement joint — low block far-left return North elevation, far left end of low block | 5.7 | m | dimensioned | high | Written dimension on the green joint. |
| 1 | Vertical EWI movement joints — low block (tower junction and far-right return) North elevation, right-hand low block | 10.2 | m | dimensioned | high | Two written dimensions on the green joints. |
| 1 | Horizontal EWI movement joints — tower curtain wall (head, No.71, No.56, No.39) North elevation, tower curtain wall | 71.4 | m | dimensioned | medium | No.39 joint dimensioned 17840.34 mm; head, No.71 and No.56 joints run between the same two vertical edges. |
| 1 | Horizontal EWI movement joint — tower base (No.21) North elevation, base of tower curtain wall at podium | 13.2 | m | dimensioned | medium | Written dimension on the green joint. |
| 1 | Spandrel / curtain-wall panel joints Tower curtain wall | not measured | m | assumed | low | Deferred to bay study [bay study drawing]; no quantity taken. |
Check on site
- p1: Confirm the written vertical dimension 46941.83 mm on the tower face — it does not match a movement joint; check it is not an extra joint or a different extent of the vertical joint.
- p1: Confirm the No.21 horizontal joint is 13155.41 mm (shorter than the 17840.34 mm joints above) and its exact endpoints.
- p1: Confirm every punched window and door size and leaf configuration against the architect's schedule (drgs [window/door schedule drawings]) before measuring perimeter sealant.
- p1: Confirm spandrel bay module, panel joint type (wet sealant or gasket) and overcill/flashing sealant from bay study [bay study drawing]; do not double-count shared mullions or the outer edge.
- p1: Confirm EWI movement joint width and sealant specification (not on this drawing).
- p1: Confirm sealing where the two power cables enter (one noted 900 mm from the corner) and where lightning downconductors pass through the EWI to the earth electrodes.
- p1: Fire-stopping and cavity barriers to be confirmed by the fire engineer; no fire rating is shown on this elevation.
- p1: Confirm whether the far-left metal gate/louvre and the first-floor louvre panel need perimeter sealant.
- p1: 156 curtain-wall/screen bays kept as a separate item, not counted as window openings.
- p1: Penetration counts are estimates: the drawing shows no fire-rated walls or floors. Confirm against the fire strategy drawings.
Assumptions
- Green facade lines are EWI movement joints per the colour key, distinct from the thinner green lightning downconductors.
- Tower vertical joint runs L2 (39110) to L14 (74705); the written 46941.83 mm vertical dimension is not reconciled to a joint and is excluded.
- Head, No.71 and No.56 horizontal joints assumed equal to the dimensioned No.39 joint (17840.34 mm) as they span the same edges.
- Joint width is not stated; metres measured are unaffected but the sealant spec needs the width.
- Curtain-wall bay module (~1490 mm, 12 across) and 13 rows are scaled estimates; internal joints assumed gasketed and excluded from wet seal pending the bay study.
- Punched-opening sizes are scaled at 1:150; door leaf sizes are typical single/double leaves (too small to scale). All to be confirmed from the schedule.
- Power-cable wall entries (2) inferred from two facade cable runs; penetration points are not explicitly shown.
- No sanitary seals or floor joints on this elevation.
- Single elevation — no double-counting across views; tags repeated in the ~5% tile overlaps counted once.
Scope notes
- North elevation only — other elevations are separate sheets and are excluded.
- Sealant scope: EWI movement joints (green, legend 'EWI MJ's'), perimeter seals to punched windows/doors, and spandrel/flashing joints.
- Opening perimeter metres are not measured here; they are derived from the openings list. Sizes must be confirmed against the window/door schedule (window/door schedule drawings) and spandrel bay study [bay study drawing].
- Sealant product and joint width are not stated; drawing to be read with the specification and product data.
- Fire strategy, cavity barrier and firestopping to be confirmed by the fire engineer (noted on sheet) — not detailed here.
AI estimate of quantities only. Not a price or a survey. Check every quantity against the drawings and on site before you quote or order.