Example drawing, not a real project

Drylining take-off: partition lengths by type

Partition lengths split by partition type from an office fit-out layout. Drawing: Office fit-out partition layout, 1:100. Read with the Plastering / drylining trade profile on 15 November 2026.

Example drawing: Office fit-out partition layout, 1:100
Example drawing drawn by QuantRead (CC BY 4.0). Download the PDF and try it yourself.

Take-off produced

ItemDetailQtyUnitConfidenceNote
P1 partition, horizontal, upper rooms / lower roomsP1 single line, 70 mm C-stud, 1 x 12.5 mm board each side20mhighPage 1
P1 partition, Office 1 / Office 2P1, upper zone only8mhighPage 1
P1 partition, Open Plan / StoreP1, lower zone only6mhighPage 1
P2 acoustic partition, Meeting 1 / Meeting 2P2 double line, 92 mm stud, 2 x 15 mm acoustic board each side, mineral wool8mhighPage 1
P2 acoustic partition, Meeting 2 / Office 1P2 double line, 92 mm stud, 2 x 15 mm acoustic board each side, mineral wool8mhighPage 1
Partition face area, Meeting 1In-scope faces only; external walls excluded; no openings deducted35.1m2mediumPage 1
Partition face area, Meeting 2In-scope faces only; external walls excluded; no openings deducted56.7m2mediumPage 1
Partition face area, Office 1In-scope faces only; external walls excluded; no openings deducted56.7m2mediumPage 1
Partition face area, Office 2In-scope faces only; external walls excluded; no openings deducted35.1m2mediumPage 1
Partition face area, Open PlanIn-scope faces only; external walls excluded; no openings deducted48.6m2mediumPage 1
Partition face area, StoreIn-scope faces only; external walls excluded; no openings deducted37.8m2mediumPage 1
Ceiling plan area, Meeting 1Plan area only; ceiling lining not specified on this sheet40m2highPage 1
Ceiling plan area, Meeting 2Plan area only; ceiling lining not specified on this sheet40m2highPage 1
Ceiling plan area, Office 1Plan area only; ceiling lining not specified on this sheet40m2highPage 1
Ceiling plan area, Office 2Plan area only; ceiling lining not specified on this sheet40m2highPage 1
Ceiling plan area, Open PlanPlan area only; ceiling lining not specified on this sheet72m2highPage 1
Ceiling plan area, StorePlan area only; ceiling lining not specified on this sheet48m2highPage 1
12.5 mm plasterboard to P1, both sides, one layerMaterial area of the P1 faces already included in wall_area_net; do not add again183.6m2mediumPage 1
15 mm acoustic board to P2, both sides, two layersBoard area is 2 layers per face; face area is half of this. Not additional to wall_area_net172.8m2mediumPage 1
Mineral wool in P2 cavityOne quilt over the partition area; thickness and density not stated43.2m2mediumPage 1

Exports from this run: CSV · PDF report

These figures are the engine’s output, unedited. In QuantRead you review every line, correct anything that is wrong and add your own items before you export or quote.

Our check against the drawing

We drew this example, so we know the figures its written dimensions give. The room face and ceiling areas are extra lines the engine added; ceilings are not in our drawing’s scope, which it noted.

ItemQuantReadFrom the drawingComment
Type P1 partitions20 + 8 + 6 = 34 m34 mMatches.
Type P2 acoustic partitions8 + 8 = 16 m16 mMatches.
12.5 mm board to P1 (both sides, 2.7 m high)183.6 m²183.6 m²34 x 2.7 x 2. Matches.
15 mm acoustic board to P2 (2 layers each side)172.8 m²172.8 m²16 x 2.7 x 2 x 2. Matches.
Mineral wool to P243.2 m²43.2 m²Matches.

No manual correction was needed on this sample.

How QuantRead measured it

Scale and sheet

Page 1 · Office fit-out level 1 - partition layout · plan · A3
Scale: 1:100 @ A3
Checked against: Not scaled. Sheet note: do not scale, use written dimensions. Closure: 5000+5000+5000+5000 = 20000; Store 8000 + Open Plan 12000 = 20000; upper 8000 + lower 600

How each line was measured

PgItemQtyUnitBasisConf.Method
1P1 partition, horizontal, upper rooms / lower rooms
Full width, under Meeting 1, Meeting 2, Office 1 and Office 2
20mdimensionedhighWritten overall width 20000 mm. Single line for the full run; P1 tag shown on the west end only.
1P1 partition, Office 1 / Office 2
Between Office 1 and Office 2
8mdimensionedhighWritten upper-zone depth 8000 mm. Runs from north external wall to the horizontal P1.
1P1 partition, Open Plan / Store
Between Open Plan and Store
6mdimensionedhighLower depth = 14000 − 8000 = 6000 mm. Runs from horizontal P1 to south external wall.
1P2 acoustic partition, Meeting 1 / Meeting 2
Between Meeting 1 and Meeting 2
8mdimensionedhighWritten upper-zone depth 8000 mm. Tagged P2 and drawn double line.
1P2 acoustic partition, Meeting 2 / Office 1
Between Meeting 2 and Office 1
8mdimensionedhighWritten upper-zone depth 8000 mm. Tagged P2 and drawn double line.
1Partition face area, Meeting 1
Meeting 1
35.1m2dimensionedmediumEast P2 8.0 m + south P1 5.0 m = 13.0 m x 2.7 m. Height from partition key, not a section.
1Partition face area, Meeting 2
Meeting 2
56.7m2dimensionedmediumWest P2 8.0 m + east P2 8.0 m + south P1 5.0 m = 21.0 m x 2.7 m.
1Partition face area, Office 1
Office 1
56.7m2dimensionedmediumWest P2 8.0 m + east P1 8.0 m + south P1 5.0 m = 21.0 m x 2.7 m.
1Partition face area, Office 2
Office 2
35.1m2dimensionedmediumWest P1 8.0 m + south P1 5.0 m = 13.0 m x 2.7 m. Room width 20000 − 3 x 5000 = 5000 mm.
1Partition face area, Open Plan
Open Plan
48.6m2dimensionedmediumNorth P1 12.0 m + east P1 6.0 m = 18.0 m x 2.7 m. Width 20000 − 8000 = 12000 mm.
1Partition face area, Store
Store
37.8m2dimensionedmediumNorth P1 8.0 m + west P1 6.0 m = 14.0 m x 2.7 m.
1Ceiling plan area, Meeting 1
Meeting 1
40m2dimensionedhigh5000 x 8000 mm.
1Ceiling plan area, Meeting 2
Meeting 2
40m2dimensionedhigh5000 x 8000 mm.
1Ceiling plan area, Office 1
Office 1
40m2dimensionedhigh5000 x 8000 mm.
1Ceiling plan area, Office 2
Office 2
40m2dimensionedhighWidth 20000 − 3 x 5000 = 5000 mm x 8000 mm.
1Ceiling plan area, Open Plan
Open Plan
72m2dimensionedhigh12000 x 6000 mm. Width 20000 − 8000; depth 14000 − 8000.
1Ceiling plan area, Store
Store
48m2dimensionedhigh8000 x 6000 mm.
1Doors / frames, each side
All rooms
not measurednrcountedlowNone drawn on this sheet. Not taken as zero; may be on another drawing.
1Angle / stop beads
All partitions
not measuredmcountedlowNot measurable. Straight runs abut walls or other partitions; beads depend on openings and finish.
1Skirting / woodwork
All rooms
not measuredmcountedlowNo skirting indicated. Quantity not guessed.
1External render
External walls
not measuredm2countedlowPlan only. External walls stated not in drylining scope.
112.5 mm plasterboard to P1, both sides, one layer
All P1, 34.0 m
183.6m2dimensionedmedium34.0 m x 2.7 m x 2 sides x 1 layer. P1 length 20.0 + 8.0 + 6.0 m.
115 mm acoustic board to P2, both sides, two layers
All P2, 16.0 m
172.8m2dimensionedmedium16.0 m x 2.7 m x 2 sides x 2 layers. Key: 2 x 15 mm each side.
1Mineral wool in P2 cavity
All P2, 16.0 m
43.2m2dimensionedmedium16.0 m x 2.7 m. Key states mineral wool but no thickness.

Check on site

  • p1: Door openings, frames and any glazing are not shown. Deduct from partition lengths and wall areas when the door schedule is available.
  • p1: Confirm 2700 mm is the lining height to soffit, and whether a deflection head is required above the partition.
  • p1: Confirm the horizontal partition is P1 for its full 20.0 m.
  • p1: Ceiling lining is not specified. Confirm whether ceilings are in the drylining package before using the plan areas.
  • p1: Board finish (skim or tape and joint) is not specified.
  • p1: Skirting is not shown.
  • p1: Angle and stop beads cannot be measured until openings and finish are known.
  • p1: Mineral wool thickness and density for P2 are not stated.
  • p1: External walls and core confirmed excluded; no elevations on this sheet for render.

Assumptions

  • Office 2 width taken as 20000 − 3 x 5000 = 5000 mm; top bays are equal and the fourth is not separately dimensioned.
  • Horizontal 8000 mm read as Store width. Open Plan width = 20000 − 8000 = 12000 mm. Lower depth = 14000 − 8000 = 6000 mm.
  • Horizontal partition treated as P1 for the full 20.0 m: tagged once, and drawn single line, not the double line used for P2.
  • Partition lengths taken wall to wall on written dimensions. Stud thickness at junctions not deducted.
  • Room areas taken to overall written dimensions. Partition and board thickness not deducted.
  • 2700 mm partition height from the key used as lining height. No floor-to-soffit section on this sheet.
  • No door or other openings deducted.

Scope notes

  • Internal partitions only. External walls and core are stated as not in drylining scope.
  • P1, single line: 70 mm C-stud, 1 x 12.5 mm plasterboard each side, 2700 mm high.
  • P2 acoustic, double line: 92 mm stud, 2 x 15 mm acoustic board each side, mineral wool, 2700 mm high.
  • No doors, openings, skirting, beads or ceiling lining are shown. Partition lengths and wall areas are gross.
  • Written dimensions used throughout.

AI estimate of quantities only. Not a price, a survey or a bill of quantities. Check every quantity against the drawings and on site before you quote or order.

Try your own drawing free

Upload one PDF drawing (up to 3 pages), pick your trade and get an editable take-off like this one.

Try it free – 1 drawing, up to 3 pagesSee pricing

More samples

Drylining take-off: partition lengths by type | QuantRead